Shenzhen Laesent Technology Co., Ltd.

APPA Toughest Digital Thermometers APPA 51/52/53II/55II

APPA Toughest Digital Thermometers  APPA 51/52/53II/55II
Product Detailed

APPA Toughest Digital Thermometer APPA 51/52/53II/55II
1).APPA-51(T1),52(T1,T2)
2).RS-232 for Optional(53II/55II)

APPA Toughest Digital Thermometer APPA 51/52/53II/55II

 

SPECIFICATIONS 
 Measurement Range: 
 APPA 51, 52
 K-type,-50~1300Celsius degree, -58~1999Fahrenheit degree

 APPA 53II, 55II
 K-type, -200~1372Celsius degree, -328~2510Fahrenheit degree
 J-type, -210~1200Celsius degree, -346~2192Fahrenheit degree

 Resolution:


 APPA 51,52
 High:0.1Celsius degree or 0.2Fahrenheit degree,
 Low:1Celsius degree or 1Fahrenheit degree
 
 APPA 53II, 55II
 0.1Celsius degree/0.1K/0.2Fahrenheit degree <=1000 degree,
 1Celsius/2Fahrenheit degree <=1000degree

 

 K-type Accuracy: 
 APPA 51, 52
 +/-(0.3%+1Celsius degree) at -50~1000Celsius degree
 +/-(0.3%+2Fahrenheit degree) at -58~1832Fahrenheit degree
 +/-(0.5%+1Celsius degree) at 1000~1300Celsius degree
 +/-(0.5%+2Fahrenheit degree) at 1832~1999Fahrenheit degree

 APPA 53II, 55II
 +/-(0.3%+1Celsius degree) at -200~-100Celsius degree
 +/-(0.3%+2Fahrenheit degree) at -328~148Fahrenheit degree
 +/-(0.1%+0.7Celsius degree) at -99.9~999.9Celsius degree
 +/-(0.1%+1.4Fahrenheit degree) at -147.8~999.9Fahrenheit degree
 +/-(0.3%+1Celsius degree) at 1000~1200Celsius degree
 +/-(0.3%+2Fahrenheit degree) at 1000~2192Fahrenheit degree

 J-type Accuracy: 
 APPA 53II, 55II
 +/-(0.3%+1.1Celsius degree) at -210~-100Celsius degree
 +/-(0.3%+2.2Fahrenheit degree) at -346~148Fahrenheit degree
 +/-(0.1%+0.8Celsius degree) at -99.9~999.9Celsius degree
 +/-(0.1%+1.6Fahrenheit degree) at -147.8~999.9Fahrenheit degree
 +/-(0.3%+1Celsius degree) at 1000~1200Celsius degree
 +/-(0.3%+2Fahrenheit degree) at 1000~2192Fahrenheit degree

 Accuracy:


 APPA52, 55II
 +/-(0.3% of T1-T2 reading +2.0Celsius degree),
 +/-(0.3% of T1-T2 reading +4.0Fahrenheit degree)

 Temperature Coefficient:


 APPA 51, 52
 0.15 x (Spec. Acc)/Celsius degree,
 <18Celsius degree or >28Celsius degree 
 
 APPA 53II, 55II
 0.1 x (Spec. Acc)/Celsius degree,
 <18Celsius degree or >28Celsius degre


 Data Logging Capacity: 
 APPA 53II, 55II
 16,000 records

 Computer Interfae 
 Software:
 
 APPA 53II, 55II
 Optical RS-232 interface

 Optional Purchase of RS-233/USB cable with WinDTM 50 software


  